全国咨询电话 15075619608

ASTP-120线缆厂家秀山点击查看更多ASTP-120线缆厂家春季

发布时间: 2025-07-12
ASTP-120线缆厂家秀山点击查看更多ASTP-120线缆厂家春季

  产品名称型号规格及范围:塑料绝缘和聚氯乙烯护套铁路信号电缆信号电缆PTYA23PTYAH,;PTYA;PZYA;PTYV;PTYY,;PTY22;PTY23;(PZY02;PZY03;PZY23PZY22)1/0.8mm(1/1.0mm)2-48芯适用于额定电压交流500V或直流1000V及以下的铁。

ASTP-120线缆厂家秀山点击查看更多ASTP-120线缆厂家春季

  4.屏蔽通信电缆工作电容:平均值52±2nF/km5.屏蔽通信电缆远端串音防卫度:150kHZ时指定组合的功率平均值大于69dB/km。HYAT实心绝缘填充型电缆用途:实心绝缘填充型电缆适用于本地电信网的城市与乡镇电信线路,也适用于接入公用网的专用网线路。

   DJVVPRDJYVPRDJYJVPR编织总屏蔽(铜丝或镀锡丝)软结构。 DJVVP2RDJYVP2RDJYJVP2R铜塑复合膜总屏蔽软结构。 DJVVP3RDJYVP3RDJYJVP3R铝塑复合膜总屏蔽软结构。

Precautions for installation of power cables: keep 2m distance when the cable is installed in parallel with the thermal pipe, and 0.5m should be maintained when crossing. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the buried depth of 1-35kv cable is not less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature is not lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter. 6 kv and above cable joint: (1) installing a cable terminal head, must be stripped semiconductor electric shielding layer, operation shall not damage the insulation, should avoid mark uneven situation, when necessary use sand paper to grind; The shield end should be flat and the graphite layer (carbon particles) should be cleaned. (2) plastic cable end copper tape screened and armor must be good grounding, the short circuit also follow this principle, avoid unbalanced three-phase run ShiGang armoured end produce inductive electromotive force, and even "lighter" and accidents such as burning sheath. It is required to use my tinplate to braid copper wire for grounding lead. When connecting with the cable copper belt, it should be welded with chromium-iron tin. The shield of three-phase copper tape should be connected with ground wire respectively. Note that the shielded ground wire and steel armor ground wire should be separately drawn out and insulated from each other. The position of the welded ground wire should be as low as possible. Basic re for cable terminals and intermediate joints: a. good conductor connection; B. The insulation is reliable, and it is recommended to use irradiated cross-linked heat-shrinkable silicone rubber insulation materials; C. good sealing; D. sufficient mechanical strength to meet various operating conditions. The end of the cable must be used to prevent erosion of water and other corrosive materials, so as to prevent breakdown due to the aging of the insulation layer caused by water trees. Crane or forklift should be used for the loading and unloading of cables. It is forbidden to run flat or lay flat. For installation of large cables, cable laying cart should be used to avoid external damage or abrasion caused by manual dragging. If the cable cannot be laid in time for some reason, it should be stored in a dry place to prevent sunlight from exploding and water entering the end of the cable. Note: the installation of wire and cable should be done by the installation personnel or full-time technical personnel familiar with the performance of wire and cable. If there are still unclear matters, please consult the relevant technical department or the technical department of our factory.

ASTP-120线缆厂家秀山点击查看更多ASTP-120线缆厂家春季

Conditions of use: cable using the environment temperature is to 40 ℃ ~ + 50; At 25 ℃ when the humidity is 95%; Cable laying temperature - 10 ℃ or higher; When laying the cable, the bending radius MHYV is 10 times of the cable outer diameter or 15 times of the cable outer diameter

1电力传动装置系统及高低压各型开关调试时,应将有关的开关手柄取下或锁上,悬挂警示牌,防止误合闸。1用摇表测定绝缘电阻,应防止有人触及正在测定中的线路或设备。测定容性或感性设备、材料后,必须放电。雷电时禁止测定线路绝缘。1电流互感器禁止开路,电压互感器禁止短路和以升压方式运行。电气设备、材料需放电时,应穿戴绝缘防护用品,用绝缘棒安全放电。1现场变配电高压设备,不论带电与否,单人值班不准超越遮栏和从事修理工作。

  耐火电缆燃烧时产生的酸气烟雾量少,耐火阻燃性能大大提高,特别是在燃烧时,伴随着水喷和机械打击的情况下,电缆仍可保持线路的完整运行。•漆包线(绕组线)又称绕组线,用于电机绕组,将电能转化为机械能。•光织光缆用于传输光信号,因具有低衰减性能,常用作长途通讯的主干线。

  带钢丝绳PVC弹性体行车控制电缆,具有柔软、耐磨、防油等特性,线旁附钢丝绳,增强抗拉力。适用于交流额定电压0.6/1KV及以下的行车、台车、传输机械等移动电器用动力传输线及控制、照明、通讯线路,本产品已广泛应用于冶金、电力、船舶、港口等行业。
  产品性能卓越,广泛应用于复杂的工业自动化控制网络及楼宇自控网络一、电缆型号:ZHT-RS486-8系(多股低电容计算机及计算机P.O.S电缆)二、执行标准:执行标准:Q/ZH09.三、产品结构示意图:四、性能参数项目单位指标1*2*24AWG(8201)2*2*24AWG(8202)1*。

  2 电缆的使用特性、分类与命名2.1 使用特性2.1.1电缆额定工作电压:450/750V、600/1000V。2.1.2电缆导体的长期工作温度:70℃。2.1.3电缆敷设时环境温度应不低于0℃。2.1.4电缆小弯曲半径:非铠装电缆:阻燃型为电缆外径的6倍,耐火型为电缆外径的12倍;铠装型电缆为电缆外径的20倍。

ASTP-120线缆厂家秀山点击查看更多ASTP-120线缆厂家春季

  4.安装敷设温度:不低于0℃5.耐火特性:符合IEC331规定符合GB/T规定火焰温度750℃火焰温度750℃燃烧时间3h燃烧时间90min冷却时间12h附加电压额定电压附加电压额定电压附加电流2A附加电流3A6.电缆允许弯曲半径:非铠装:应不小于电缆外径的8倍铠装:应不小于电缆外径的12倍三、产品。

  /U:450/750V;3、小弯曲半径:非铠装电缆不小于电缆外径的6倍;铠装电缆不小于电缆外径的12倍。在交联聚乙烯绝缘高阻燃的基础上又开发了低烟无卤高阻燃隔氧层电力电缆,其低烟无卤性能符合国家标准GB/T17651.1.2和GB/T17650.1.2。

但是走顶的管道,只需将墙皮破坏掉即可,维修后的修补也比破坏地面方便、便宜的多。如果碰巧了你的管道坏在了吊顶内的话,则只需要拆下吊顶即可,维修成本更低、可操作性更大。好处漏水快发现住楼房,烦心的事情就是管道漏水——多数时候,法院受理的邻里纠纷类案件,六七成都是由于楼上漏水给楼下住户带来损失导致的。为什么楼上管道漏水会流到楼下去呢?想来无非是两个原因——1.漏水点没有及时发现;2.漏水导致破损管道附近积水。

  使用条件:防水电缆线长期允许工作温度65℃。产品适用于潜水泵,煤矿,水下作业,水中景光灯等水处理设备,该产品采用高密度胶具有防水等功能用途:本产品用于计算机和自动化设备连接用电缆,它具有抗干扰、信号衰减小等性能。

ASTP-120线缆厂家秀山点击查看更多ASTP-120线缆厂家春季
  ◎增压级-CMP级(送风燃烧测试/斯泰钠风道实验PlenumFlameTest/SteinerTunnelTest)这是UL防火标准中要求高的电缆(PlenumCable),适用安全标准为UL910,实验规定在装置的水平风道上敷设多条试样,用87.9KW煤气本生灯(300,000BTU/Hr)燃烧。

  使用条件1:使用温度(℃):-40~+602:相对温度:40℃时达98%3:安装敷设温度不低如:-15℃4:充许小弯曲半径:室内不小于5倍,室外10倍结构1:镀锡铜丝线芯2:聚氯乙烯绝缘3:薄膜绕包4聚氯乙烯护套额定电压:300V/300V 300V/500V采用标准:GB/T。

  6、对称的三芯电缆结构设计,具有比四芯电缆更好的传输性能。变频电缆的设计变频装置的节能效果十分明显,在大功率电机中采用变频调速电机,整个发电机组可节电30%。并且使用变频调速后,实现了电机的软启动,使电机工作平稳,电机轴承磨损减小,延长了电机使用寿命和维护周期。

联系方式

  • 地址:天津 河北省廊坊市大城县毕演马工业园
  • 邮编:65900
  • 电话:0316-5961400
  • 销售部总经理:王艳
  • 手机:15075619608
  • 传真:0316-5961400
  • 微信:15075619608
  • QQ:1062174610
  • Email:526183977@qq.com