NH-KFFP2耐火控制屏蔽电缆慧眼7X0.5



设计使用循环弯曲寿命为500万次,实际使用已超过600万次。通常HYA通信电缆分为:10对,20对,30对,50对,100对,200对,300对。。。。。2400对。。有一小把是用“白兰”标识线缠着的,另有5对线用“白桔”标识缠着。
耐火电缆是指在火焰燃烧情况下能够保持一定时间安全运行的电缆。我国国家标准GB12666.6(等IEC331)将耐火试验分A、B两种级别,A级火焰温度950~1000℃,持续供火时间90min,B级火焰温度750~800℃,持续供火时间90 min,整个试验期间,试样应承受产品规定的额定电压值。耐火电缆广泛应用于高层建筑、地下铁道、地下街、大型电站及重要的工矿企业等与防火安全和消防救生有关的地方,例如,消防设备及紧急向导灯等应急设施的供电线路和控制线路。凤冈
耐火电缆使用条件:1.交流额定电压:U。/U(V系列:600/1000V,K系列:450/750V,B系列:450/750V)。2.电缆高长期工作温度(1)阻烯聚坲乙烯绝缘及护套:70℃和105℃两种;交联聚乙烯绝缘:90℃;(2)氟塑料绝缘和护套:220℃和260℃两种;氟塑料绝缘和105℃阻燃聚氟乙烯护套:90℃和125℃两种。(3)低卤低烟阻燃PVC绝缘和护套:70℃;无卤低烟阻燃绝缘和护套:90℃和125℃两种。3.低环境温度:(1)阻燃聚氯乙烯绝缘和护套:固定敷设-40℃;非固定敷设-15℃;(2)氟塑料绝缘和护套:固定敷设-60℃;非固定敷设-20℃;4.电缆安全敷设温度不应低于0℃。
(注意:这25对用“白兰”标识线缠着)1对—白兰2对—白桔3对—白绿4对—白棕5对—白灰6对—红兰7对—红桔8对—红绿9对—红棕10对—红灰11对—黑兰12对—黑桔13对—黑绿14对—黑棕15对—黑灰16对—黄兰17对—黄桔18对—黄绿19对—黄棕20对—黄灰21对—紫兰22对—紫桔23对—紫绿24。

煤矿用聚氯乙稀绝缘和护套阻燃控制电缆天津市电缆厂MKVVMKVV22MKVV32MKVVRMKVVRPMKVV(2-61芯)MKVV芯) MKVVR (2-61芯)MKVV芯) MKVVP (2-61芯)煤矿用阻燃屏蔽通信电缆MHYVP一、产品用途及特点本产品适用于矿山、井下环境监控系统中传输通信。
plc模拟量输入输出都会涉及到数据类型的互转问题,然而西门子300系统对于数据格式有着明确的规定,一般的四则运算都是在同一数据类型下才能进行的,这也是一直以来困扰初学者的一个问题。西门子300编程软件step7和博图都提供了相应的模拟量输入输出处理模块FC105,FC106。但是好多场合下,要对数据进行线性转换或运算,靠这两个函数是远远不够的。这时候就需要用户自己动手写一些数据转换的子程序。所以知道西门子数据类型转换是很有必要的。
DJYJV(R)P交联聚乙烯绝缘铜丝编织总屏聚氯乙烯护套计算机用屏蔽(软)电缆。DJYJPV(R)交联聚乙烯绝缘铜丝编织分屏聚氯乙烯护套计算机用屏蔽(软)电缆。DJYJPV(R)P交联聚乙烯绝缘铜丝编织分屏总屏聚氯乙烯护套计算机用屏蔽(软)电缆。
分别用ZR、ZRD、ZRDW型号表示。如编织钢丝铠装氟塑料护套表示为“94”。4.电缆允许小弯曲半径:非铠装、联锁或编织铠装电缆不小于电缆外径的6倍铜带屏蔽或钢丝、钢带缠绕铠装电缆不小于电缆外径的12倍5.阻燃特性:符合GB/T19666-2005标准,A类或B类。
我国国家标准GB12666.6(等同IEC331)将耐火试验分A、B两种级别,A级火焰温度950~1000℃,持续供火时间90min,B级火焰温度750~800℃,持续供火时间90min,整个试验期间,试样应承受产品规定的额定电压值。
Precautions for installation of power cables: keep 2m distance when the cable is installed in parallel with the thermal pipe, and 0.5m should be maintained when crossing. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the buried depth of 1-35kv cable is not less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature is not lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter. 6 kv and above cable joint: (1) installing a cable terminal head, must be stripped semiconductor electric shielding layer, operation shall not damage the insulation, should avoid mark uneven situation, when necessary use sand paper to grind; The shield end should be flat and the graphite layer (carbon particles) should be cleaned. (2) plastic cable end copper tape screened and armor must be good grounding, the short circuit also follow this principle, avoid unbalanced three-phase run ShiGang armoured end produce inductive electromotive force, and even "lighter" and accidents such as burning sheath. It is required to use my tinplate to braid copper wire for grounding lead. When connecting with the cable copper belt, it should be welded with chromium-iron tin. The shield of three-phase copper tape should be connected with ground wire respectively. Note that the shielded ground wire and steel armor ground wire should be separately drawn out and insulated from each other. The position of the welded ground wire should be as low as possible. Basic re for cable terminals and intermediate joints: a. good conductor connection; B. The insulation is reliable, and it is recommended to use irradiated cross-linked heat-shrinkable silicone rubber insulation materials; C. good sealing; D. sufficient mechanical strength to meet various operating conditions. The end of the cable must be used to prevent erosion of water and other corrosive materials, so as to prevent breakdown due to the aging of the insulation layer caused by water trees. Crane or forklift should be used for the loading and unloading of cables. It is forbidden to run flat or lay flat. For installation of large cables, cable laying cart should be used to avoid external damage or abrasion caused by manual dragging. If the cable cannot be laid in time for some reason, it should be stored in a dry place to prevent sunlight from exploding and water entering the end of the cable. Note: the installation of wire and cable should be done by the installation personnel or full-time technical personnel familiar with the performance of wire and cable. If there are still unclear matters, please consult the relevant technical department or the technical department of our factory.
耐火电缆的耐火特性:符合IEC331规定 符合GB12666.6规定 :火焰温度750℃ 火焰温度 950℃-1000℃ 火焰温度 750℃-800℃ 燃烧时间 3h 燃烧时间90min 燃烧时间90min 冷却时间 21h 附加电压 额定电压 附加电压 额定电压附加电压 额定电压 附加电流 3A 附加电流 3A附加电流 3A A类 B类6.敷设推荐的允许弯曲半径:非铠装、编织屏蔽电缆应不小于电缆外径的6倍;钢带铠装电缆应不小于电缆外径的12倍;氟塑料绝缘和护套材料电缆应不小于电缆外径的8倍。
燃烧特性代号表:代号 名称Za 阻燃ZA 阻燃A类ZB 阻燃B类ZC 阻燃C类ZDb阻燃D类省略 有卤W 无卤D 低烟U 低毒N 耐火NJ 耐火加冲击NS 耐火加喷水a Z为单根阻燃,仅用于基材不含卤素的产品。基材含卤素的,Z省略。b ZD为成束燃烧D类,适用于外径不大于12mm即较细的产品。
两者之间经过一条通信线路(通常是RS422)联系在一起,使得它们得以共享所有的信息资源。也就是说,PLC中所有供用户使用的软件资源,即数据寄存器、状态寄存器、定时器、计数器等,在GOT中也有完全相同的一套镜像。其中任何一台计算机,无论因何种原因,以何种方式,改变了任何资源中的任何信息,都会在另一台计算机中立即被复制。也可以说,因为两者之间的即时通信,使得两者的信息资源互为镜像。这种既独立又分工的协作关系,使得它们能够出色地完成共同的任务。
2、绝缘材料:高密度聚乙烯或聚丙烯,按照全色谱标准标明绝缘线的颜色。3、绝缘线对:把二根不同颜色的绝缘线按不同的节距扭绞成对,并采用规定的色谱组合以便识别线对。4、通信电缆缆芯结构:以1对为基本单位,超过25对的电缆按单位组合,每个单位用规定色谱的单位扎带绕扎,以便识别不同的单位。
电缆直埋安装时,1-35KV电缆直埋深度不小于0.7m。 10KV及以下电缆平行安装时,相互净距不小于0.1m,10-35KV不小于0.25m;交叉安装时距离不小于0.5m。 电缆敷设温度不低于0℃,弯曲半径:多芯电缆≥15(D+d),单芯电缆≥20(D+d),(D为电缆外径,d为导体外径)。