福泉采煤机屏蔽橡套软电缆MCP-0.38/0.66振奋



福泉采煤机屏蔽橡套软电缆MCP-0.38/0.66振奋
Specializing in the production for the telecommunications, computing facilities, instruments and meters connect with wire and cable series product -- -- -- -- -- - RVVP coal RVV series of products: coal mine product logo - logo - Ann Ann symbol certification - coal Ann query - AnBiao query on a coal production license MA for certification to provide coal mine product logo AnBiao certificate, MA certificate, Ann card flame retardant communication cable MHYV MHJYV MHYBV MHYA32 MHYYV MHYY32 flame retardant cable: MHYVR MHYBV MHYV32 MHYVR MHYVP MHYBV MHYVR32 coal mine fire retardant control cable: HYA22 zrc-hya zrc-hyat zrc-hyat23 HYA23 HYA53 HYAT HYAT23 HYAT53 HYAC HJVV HPVV HPVV22 PYV azv HYV22 PYV22 control cable: KVV KVVP kvvv22 kvp2 kvp2 kvp2-22 KVVR KVRP special cable HP KP H Your satisfaction - our unremitting pursuit!
HYAT22:铜芯实心聚烯烃绝缘填充式挡潮层聚乙烯护套钢带铠装聚氯乙烯护套市内通信电缆。HYAT23:铜芯实心聚烯烃绝缘填充式挡潮层聚乙烯护套钢带铠装聚乙烯护套市内通信电缆。HYV:铜芯实心聚烯烃绝缘聚氯乙烯护套市内通信电缆。
由于含卤阻燃电缆(包括阻燃电缆、低卤低烟阻燃电缆)在燃烧时会释放具有腐蚀性的卤酸气体,大大阻碍消防工作从而耽误救火时间并加剧火势蔓延,因此在人口密度较高的公众场所应尽量设计选用无卤低烟阻燃电缆。在人口密度较小的作业区可以选用任意一种阻燃电缆。阻燃电缆分为A、B、C3类,其中A类阻燃电缆性能较B、C类更优,价格也贵。设计人员提供订货清册时应标明阻燃电缆的类别。从外观上无法区分阻燃电缆的A、B、C类别,只有靠制造厂家进行供货保证,因此在设计选用时应慎重选择电缆制造厂家。福泉采煤机屏蔽橡套软电缆MCP-0.38/0.66振奋
MHYBV(HUYBV)矿用聚乙烯绝缘、镀锌钢丝编织铠装、阻燃聚氯乙烯护套通信电缆。MHYAV(HUYAV)矿用聚乙烯绝缘、铝/聚乙烯粘结护层、阻燃聚氯乙烯护套通信电缆。MHYA32(HUYA32)矿用聚乙烯绝缘、铝/聚乙烯粘结护层、镀锌钢丝铠装、阻燃聚氯乙烯护套通信电缆。

6、对称的三芯电缆结构设计,具有比四芯电缆更好的传输性能。变频电缆的设计变频装置的节能效果十分明显,在大功率电机中采用变频调速电机,整个发电机组可节电30%。并且使用变频调速后,实现了电机的软启动,使电机工作平稳,电机轴承磨损减小,延长了电机使用寿命和维护周期。
READ_VAR,WRITER_VAR,才是我们要真正使用的,它的作用就是写入和读取变量,看程序图六CFC编写的MODBUS通信程序如图六所示,是程序的全貌,程序实在太大了,大家可能要费点眼神了,黄色荧光笔部分是程序的启动按钮,当变量Com_En产生一个上升沿时,程序就会自动执行。后面红色大圆圈就是我们需要的结果。读取或写入的数据是放在数组里的,当你交互的数据是连续的时候,就很方便了。其实,CFC的精髓就是可以自由移动,就像电路图一样,像通讯程序中,由于前后功能块需要联系,我们就需要中间变量来传递,而直接使用连线,省去了建立中间变量的麻烦。
无卤低烟阻燃电缆和含卤阻燃电缆相比,有低腐蚀、低烟的优点,但电性能及机械性能明显降低,所以在进行电缆敷设时,无卤低烟阻燃电缆应较含卤阻燃电缆有更大的弯曲半径。在进行电缆敷设设计时,不宜将非阻燃电缆和阻燃电缆并列敷设,不宜将不同阻燃类别的阻燃电缆并列敷设。
阻燃电缆标准:电缆涉及火灾安全的主要技术指标是CO2电缆的阻燃性、烟雾的密度和气体的有毒性。美国防火标准较关注前两个问题,但是欧洲和美国对火灾安全有着完全不同的观点。
美国传统的概念认为:火灾的根源在于一氧化碳(CO)毒气的产生以及其后的燃烧过程中CO转化为CO2的热释放,因此,控制燃烧过程中的热释放量可减少火灾的危害。欧洲传统以来深信:在燃烧中产生的卤酸(HCL)释放量、气体腐蚀性、烟雾浓度及气体毒性是决定人们能否安全脱离火灾现场的主要因素。
1. Wire: annealed bare copper wire with a diameter of 0. 30, 0. 42, 0. 52, 0. 60, 0. 70, 0. 80, 0. 90 (mm). 2. Insulation material: high density polypropylene or polypropylene, color of the insulation line according to the whole chromatogram. 3. Pair of insulated wires: twisted two insulated wires of different colors into pairs according to different pitch, and used the specified chromatographic combination to identify the pairs. 4. Communication cable core structure: take 1 pair as the basic unit, more than 25 pairs of cables are combined according to units, and each unit is wired with the unit of specified chromatogram in order to identify different units. 100 pairs of cables with more than one pair of cables plus 1% of the reserve pair, but not more than 6 pairs. The gap in the core is filled with oil paste. 5. Core wrap belt: wrap with polyester film tape. 6. Shielding: copper wire shielding or metal strip with or without striping, which is longitudinal wrapped outside the core of communication cable. 7. Sheath: blue low-density polymer. Communication cables with double sheaths can also be provided.
型号:ZRC-HYA阻燃通信电缆,WDZ-HYA无卤阻燃通信电缆,ZR-HYA阻燃通信电缆,MHYA矿用通信电缆技术特点:防火阻燃低损耗低色散结构紧凑良好的综合机械性能应用范围:适用于矿山、电厂、市内、近郊及局部地区,起到防火阻燃作用。

MHYBV(PUYBV)煤矿用聚乙烯绝缘镀锌钢丝编织铠装阻燃聚氯乙烯护套通信电缆5-501/0.8用于机械冲击较高的平巷、斜巷煤矿用阻燃通信电缆……mh聚乙烯绝缘……Y铜质线芯……省落铝-聚乙烯粘结护层……A聚乙烯内护层……省落铜丝编织铠装……B蓝阻燃聚氯乙烯护套……V钢丝铠装蓝阻燃聚氯乙烯护。
为了评定线缆的阻燃性能优劣,国际电工委员会分别制定了IEC60332-1、IEC60332-2和IEC60332-3三个标准。IEC60332-1和IEC60332-2分别用来评定单根线缆按倾斜和垂直布放时的阻燃能力(国内对应GB12666.3和GB12666.4标准)。IEC60332-3(国内对应GB12666.5-90)用来评定成束线缆垂直燃烧时的阻燃能力,相比之下成束线缆垂直燃烧时在阻燃能力的要求上要高得多。
IEC60332-1/BS4066-1阻燃等级(单根电线或电缆垂直燃烧测试FlameTestONSingleVerticalInsulatedWires/Cables)
1在高压带电区域内部分停电工作时,人体与带电部分,应保持规定的安全距离,作业时并必须有人监护。变配电室内、外高压部分及线路,停电工作时:1切断有关电源,操作手柄应上锁或挂标示牌。2验电时应戴绝缘手套,按电压等级使用验电器,在设备两侧各相或线路各相分别验电。3验明设备或线路确认无电后,即将检修设备或线路做短路接地。4装设接地线,应由两人进行,先接接地端,后接导体端,拆除时顺序相反。拆、接时均应穿戴绝缘防护用品。
IEC和IEC分别用来评定单根线缆按倾斜和垂直布放时的阻燃能力(国内对应GB12666.3和GB12666.4标准)。IEC国内对应GB12666.5-90,GB12666.5已经被GB/T18380.3-2001代替)用来评定成束线缆垂直燃烧时的阻燃能力,相比之下成束线缆垂直燃烧时在阻燃能力的要求上要高得多。