孟冬矿用监控电缆MHY32西



孟冬矿用监控电缆MHY32西
型号产品名称敷设场合及要求芯数标称截面mm2导体长期允许工作温度℃245IEC81(YH)高强度橡套电焊机电缆用作电焊机二次侧接线及连接电焊钳的软电缆116~9565YH天然胶护套电焊机电缆用作电焊机二次侧接线及连接电焊钳的软电缆110,120~18565245IEC8。
矿用信号电缆是一种信号传输工具。一般信号电缆传输的信号很小,为了避免信号受到干扰,信号电缆外面有一层屏蔽层,包裹的导体的屏蔽层,一般为导电布,编织铜网或铜泊(铝),屏蔽层需要接地,外来的干扰信号可被该层导入大地,避免干扰信号进入内层导体干扰同时降低传输信号的损耗。
矿用信号电缆主要技术性能及指标:20℃时导体直流电阻 Ω/km 7/0.28 ≤45 7/0.28(3钢4铜)≤73 1/0.8≤36.7固有衰减(800~1000HZ) dB/km ≤1.1 ≤1.3 ≤0.95
20℃时电缆绝缘线芯绝缘电阻 MΩ.km
≥3000 线对工作电容(800~1000HZ) uF/km ≤0.06 近端串音衰减(800~1000HZ) dB/500m ≥70 电感(800~1000HZ) uH/km ≤800 耐交流工频电压 1.5KV/1min通过 直流电阻差 ≤环阻的2%
矿用信号电缆的使用特性:导体的长期允许工作温度-40~+50℃;平均大相对湿度为≤95%(+25℃时)允许附设与安装的温度应不大于-10℃ 小弯曲半径:MHYV、MHJYV型电缆为电缆外径的10倍,其它型号的电缆为外径的15倍
矿用信号电缆|MHYV矿用信号电缆|MHYVR矿用信号电缆|MHYVP矿用屏蔽信号电缆|MHY32矿用信号电缆|MHYVRP矿用屏蔽信号电缆|矿用监测电缆
Half air insulated cable: this kind of structure is between these two kind of insulation type, its insulation is also made up by air and solid medium, but from one conductor to another conductor need through the solid dielectric layer.
ZR-BPYJVP3交联聚乙烯绝缘聚氯乙烯护套铝聚酯复合膜绕包屏蔽变频电力电缆。1、产品执行标准:MT2、用途:本产品适用于交流额定电压u0/u为450/750V及以下的控制监控回路及保护线路和配电装置中电器仪表的连接线。

第四的25对是用“白棕”标识线缠着的。第五的25对是用“白灰”标识线缠着的。第六的25对是用“红兰”标识线缠着的。第七的25对是用“红桔”标识线缠着的。第八的25对是用“红绿”标识线缠着的。主要电气性能:1.直流电阻:20℃,0.5mm铜线,小于等于95Ω/km。
二次仪表故障。这部分故障较多,包括:一次仪表电路板有断线之处,量程设定有个别位显示坏,K系数设定有个别位显示坏,使得无法确定量程设定以及K系数设定,这部分原因主要向问题、有关。通过修复相应的故障,问题得以解决。四路线路连接问题。部分回路表面上看线路连接很好,仔细检查,有的接头实际已松动造成回路中断,有的接头虽连接很紧但由于副线问题紧固螺钉却紧固在了线皮上,也使得回路中断,这部分原因主要同问题有关。
矿用信号电缆,适用于矿场作信号传输,可移动或固定使用。
矿用阻燃信号电缆(现统称煤矿用阻燃通信电缆) 矿用监控电缆MHY326X2X7/0.37
产品采用标准:MT818-1999 本产品用于煤矿井下监测、控制系统中低频信号传输线。
使用条件 :电缆使用环境温度为-40℃~+50℃;在25℃时湿度为95%;电缆敷设温度≥-10℃;电缆敷设时的弯曲半径MHYVR和MHYBV≥10倍电缆外径,其余型号≥15倍电缆外径。
●用途主要用于煤矿井下监测、监控、轨道运输系统作信息传输线,也可用于通讯系统作信息传输。
使用条件 ●环境温度:-40~50℃ ●月平均大相对温度:95%(+25℃) ●安装敷设环境温度:≥-10℃
●安装时小弯曲半径:MHYV、MHJYV为电缆外径的10倍,其他型号为电缆外径的15倍
电缆使用环境温度-40℃ ~ +50℃,电缆敷设温度≥-10℃,在25℃时的温度≤95%,电缆敷设时弯曲半径: MHYV31、MHYV型电缆≥ 10倍电缆外径 其余型号电缆≥15倍电缆外径
四、动力电缆安装注意事项、使用特性及运行敷设条件1、动力电缆安装注意事项电缆与热力管道平行安装时保持2m的距离,交叉时应保持0.5m。电缆与其它管道平行或交叉安装时均要保持0.5m的距离。电缆直埋安装时,1-35KV电缆直埋深度不小于0.7m。

This product USES features: 1.1 the use of the cable temperature - 40 ℃ ~ + 60 ℃. 1.2 cable conductor long-term working temperature shall not exceed + 70 ℃. Cable laying temperature 1.3: PVC sheathed cable should not below 0 ℃; Polyethylene outer sheath cable should be not less than 20 ℃. 1.4 allowable bending radius of cables: non-armoured cables shall be no less than 10 times of the outer diameter of cables; The armored cable shall not be less than 15 times the outer diameter of the cable. 1.5 the ideal shielding coefficient of comprehensive sheathed railway signal cable is less than 0.8; The ideal shielding coefficient of aluminum sheath railway signal cable is less than 0.3
耐火电缆选用根据耐火电缆的具体特性,设计人员在设计选用时应注意以下几个问题:(1)当耐火电缆用于电缆密集的电缆隧道、电缆夹层中,或位于油管、油库附近等易燃场所时,应首先选用A类耐火电缆。除上述情况外且电缆配置数量少时,可采用B类耐火电缆。
在各种金属加工中,常应用到切削液,作为加工的润滑、防锈、冷却以及清洗的润滑油品。目前切削液的大致分为乳化液、微乳化液以及合成切削液。当切削液使用一段时间后,会出现变质问题,此时加美润滑油建议:应当考虑换油或者分析变质的原因并采取解决方案。切削液变质的原因一是由于各种添加剂的磨耗掉,此时属于正常的变质,另一个原因就是由于使用不当导致切削液被厌氧细菌所污染,从而加速了切削液的发臭和变质。切削液的更换需注意哪些问题呢?要清洗干净水槽和水箱,一般是先用清水冲洗,然后配制有一定浓度比的切削液溶液清洗,后让切削液配制好在机器中旋转15分钟左右;确保更换的是同一类型的切削液,不能随意更换切削液;在配制切削液的时候,尤其是乳化液的配制时,需要注意应当先加水然后再将原液倒入水中,否则在溶液还没有乳化均匀情况下,容易影响切削液的各种功能。
型号名称主要用途铜芯铝芯YJVYJLV交联聚乙烯绝缘聚氯乙烯护套电力电缆敷设于室内,隧道、电缆沟及管道中,也可埋在松散的土壤中,电缆能承受一定的敷设牵引YJV22YJLV22交联聚乙烯绝缘钢带铠装氯乙烯护套电力电缆适用于室内、隧道、电缆沟及地下直埋敷设,电缆能承受机械外力作用,。