Call communication cable product features low cable of rated voltage: the minimum working temperature is not lower than 500 v low cable - 40 ℃. The highest long-term low cable allows working temperature: polyethylene insulation is not higher than 70 ℃; Cross-linked polyethylene insulation is not higher than 90 ℃. Low cable temperature: the minimum 0 ℃. Preheat if below minimum laying temperature. 's main electric cable performance: (l) 20 ℃ conductor dc resistance: 0.75 was no more than 26 / km; 2.0 was no greater than 9.8 Ω/km (2) 20 ℃ when the cable insulation resistance: 0.75 was not less than 300 m Ω • km; 2. Om Ω • Omm2 not small to 10 km. (3) voltage test between cable core and cable core, and between wire core and shield through ac 2500V/5min. (4) the working capacitance of the cable set shall not exceed 100pF/m when the test frequency is 1kHz. (5) the capacitance imbalance of the cable set shall not be greater than 250pF when the test frequency is lkHz and the cable length is 250Im. The combustion characteristics of the ending cable
三. 产品名称及型号HJVV铜芯聚氯乙烯绝缘和护套局用电缆HJVVP铜芯聚氯乙烯绝缘和护套屏蔽型局用电缆四. 规格尺寸及重量规格导体直径MM芯数电缆计算直径MM电缆重量KG/KMHJVV6×2×0.50.5127.1860.52HJVV5×3×。
由于含卤阻燃电缆(包括阻燃电缆、低卤低烟阻燃电缆)在燃烧时会释放具有腐蚀性的卤酸气体,大大阻碍消防工作从而耽误救火时间并加剧火势蔓延,因此在人口密度较高的公众场所应尽量设计选用无卤低烟阻燃电缆。在人口密度较小的作业区可以选用任意一种阻燃电缆。阻燃电缆分为A、B、C3类,其中A类阻燃电缆性能较B、C类更优,价格也贵。设计人员提供订货清册时应标明阻燃电缆的类别。从外观上无法区分阻燃电缆的A、B、C类别,只有靠制造厂家进行供货保证,因此在设计选用时应慎重选择电缆制造厂家。留坝MCP矿用橡套电缆活气
MHYV mine resistance net line MHYV mine net line 4*2*0.5,MHYV mine net line 4*2*0.8 standard 568A:

适用于穿管或电缆槽、架、沟内敷设。标称截面(mm2)20。C时导体电阻RVVZ;特点:交换机动力电缆传输专用电缆,具有柔软、易弯曲、阻燃等优点。 VV-不阻燃,硬动力电缆,不易弯曲,适用于固定敷设。
“三相电”的概念是:线圈在磁场中旋转时,导线切割磁场线会产生感应电动势,它的变化规律可用正弦曲线表示。如果我们取三个线圈,将它们在空间位置上相差点120度角,三个线圈仍旧在磁场中以相同速度旋转,一定会感应出三个频率相同的感应电动势。由于三个线圈在空间位置相差点120度角,故产生的电流亦是三相正弦变化,称为三相正弦交流电。工业用电采用三相电,如三相交流电动机等。任两相之间的电压都是380VAC,任一相对地电压都是220VAC。
无卤低烟阻燃电缆和含卤阻燃电缆相比,有低腐蚀、低烟的优点,但电性能及机械性能明显降低,所以在进行电缆敷设时,无卤低烟阻燃电缆应较含卤阻燃电缆有更大的弯曲半径。在进行电缆敷设设计时,不宜将非阻燃电缆和阻燃电缆并列敷设,不宜将不同阻燃类别的阻燃电缆并列敷设。
阻燃电缆标准:电缆涉及火灾安全的主要技术指标是CO2电缆的阻燃性、烟雾的密度和气体的有毒性。美国防火标准较关注前两个问题,但是欧洲和美国对火灾安全有着完全不同的观点。
美国传统的概念认为:火灾的根源在于一氧化碳(CO)毒气的产生以及其后的燃烧过程中CO转化为CO2的热释放,因此,控制燃烧过程中的热释放量可减少火灾的危害。欧洲传统以来深信:在燃烧中产生的卤酸(HCL)释放量、气体腐蚀性、烟雾浓度及气体毒性是决定人们能否安全脱离火灾现场的主要因素。
In addition, once the halogenated body reacts with the water in the air, it will generate "halogenated hydrogen acid", which will seriously corrode e and buildings and cause "secondary disasters".
例如,常用的电话线直径为24AWG的线径约为0.5mm(0.2mm2),26AWG,约为0.4mm(0.13mm2),AWG数值越大线径越小,平方越小。如果传输距离达不到以上数字,除了布线环境干扰恶劣外,那就是电缆的质量问题。

电力电缆,铠装电缆,地埋电缆一、产品简介: 电力电缆用输配电系统,本公司生产的交流额定电压0.6/1KV聚氯乙烯绝缘电力电缆和35KV及以下交联聚乙烯电力电缆,其性能不仅符合标准GB1276和IEC60502及IEC60840,并且已形成系列,即阻燃型的、耐火型的、耐寒型的和防水型的电力电缆。
为了评定线缆的阻燃性能优劣,国际电工委员会分别制定了IEC60332-1、IEC60332-2和IEC60332-3三个标准。IEC60332-1和IEC60332-2分别用来评定单根线缆按倾斜和垂直布放时的阻燃能力(国内对应GB12666.3和GB12666.4标准)。IEC60332-3(国内对应GB12666.5-90)用来评定成束线缆垂直燃烧时的阻燃能力,相比之下成束线缆垂直燃烧时在阻燃能力的要求上要高得多。
IEC60332-1/BS4066-1阻燃等级(单根电线或电缆垂直燃烧测试FlameTestONSingleVerticalInsulatedWires/Cables)
三相电源中流过每相负载的电流为相电流,用IAIBICA表示。对于星型接法的电动机,相电流等于线电流,对于三角形接法的电动机,线电流等于根号3相电流在星形联接的负载中,流过端线的线电流等于流过负载的相电流,流过中线的中线电流等于各相电流的矢量和。在三角形联接的负载中,相电压等于线电压(各相负载两端的电压仍称为相电压)。一般总是三相负载对称的才接成三角形接法,此时三个线电流对称,三个相电流也对称,线电流等于相电流的“根号3”倍。
AVVR型300/300V铜芯聚氯乙烯绝缘聚氯乙烯护套安装用软电缆。KVVP2聚氯乙烯绝缘,聚氯乙烯护套铜带绕包屏蔽控制电缆同上。KVV22聚氯乙烯绝缘,聚氯乙烯护套内钢带铠装控制电线敷设在室内、电缆沟中、管道内及地下,能承受较大的机械外力使用。
- 北碚低压电力电缆答应 2025-03-27
- 城采煤机屏蔽橡套软电缆MCP-0.38/0.66韶晖 2025-03-27
- 榕城煤矿采煤机及类似设备的电源连接电缆早熟 2025-03-27
- 安国矿用橡套电缆MYP-打春 2025-03-27
- 攸县MY-0.38/0.66矿用移动橡套软电缆4X120 2025-03-27
- 随县MYP-0.38/0.66矿用移动屏蔽橡套软电缆春装 2025-03-27
- 惠阳MCP-0.38/0.66采煤机屏蔽橡套软电缆莺莺 2025-03-27
- 桦川矿用橡套电缆MYP-晨曦 2025-03-27
- 嘉黎低烟无卤电力电缆WDZ-眺望 2025-03-27
- 上栗采煤机屏蔽橡套软电缆UCP-0.38/0.66冬季 2025-03-27
- 弋阳五芯矿用橡套电力电缆4X16 2025-03-27
- 荣昌矿用橡套电缆MY-2X4 2025-03-27
- 铜陵钢带铠装电力电缆失望 2025-03-27
- 施甸矿用橡套电缆MZ-秀气 2025-03-27
- 铜陵钢带铠装电力电缆1X1.5 2025-03-27